906 GABIONS

From SHA MediaWiki
Jump to navigation Jump to search
This is not a legal document. Please see disclaimer for more information.
906.01 WIRE FOR GABIONS
A370. All wire including tie and connecting wire shall have a tensile strength of at least 60 000 psi. All wire sizes and mesh spacing shall be as recommended by the manufacturer.
Stainless steel interlocking fasteners meeting A313 may be substituted for wire ties. Fasteners shall remain in a closed and locked condition when subjected to directional tension along its axis at a minimum force of 900 lb.
906.01.01 Galvanized Coating for Gabions. A123. Galvanize fabric, ties, and connecting wire to at least 0.8 oz/ft2.
906.01.02 Polyvinyl Chloride (PVC) Coating for Gabions. Test per MSMT 508. PVC coating for fabric, ties, and connecting wires shall exhibit no weight loss. Color number shall meet AMS-STD-595 gray, No. 26440 or green No. 24533 and match throughout the project.